Firmware - Release 1.0.0 Alpha 5 (20241018)
Changes since last release:
- Fix some throttle by wire issues on the 600
- Allow power to stay on during stepper homing.
- Add config error for EGATE min/max backwards
- Add VR/hall selectors for SS inputs. (600)
- Fix config error number for stepper.
- Based on testing, make EGO delay longer on transients with large lambda error, and increase overall delay by 15%.
- Allow SWPWM and HWPWM outputs to be tested from Wiring Overview.
- In open-loop boost with dome, boost target shows 0 to avoid confusion.
- vss_out working.
- cel using features/pins. XML work.
- Add range check for frequency option in Generic PWM outputs
- Enable Nitrous control
- Rename 600 pins
- Move C6/C7 into outputs group (were pinsetting 44,45; now 158,159)
- Set default Baro to baro on 600.
- Assign default fields to internal logging and enable by default.
- Add powercycle requirement to several fields/pins
- Make pin name show for ADCs (one line missing.)
- Pit limiter works
- Torque Convertor Lockup works
- Sequential shift cut works
- Water injection works
- Tableswitching fully works
- Change "rpm" units to "RPM" for consistency. (Was a mix of both.)
- Dual Fuel works
- Fix nasty bug where Staging was always partially enabled and in some situations changing PW2
- Add config error check for injector outputs not configured.
- Anti-lag works
- Custom CL/PID works
- Lambda safety / engine shutdown work
- Water injection link to shutdown
- EGT safety test and tweak default data.
- Oil pressure safety works
- Fuel pressure safety works
- Custom on/off outputs:
- Was reading wrong threshold for second condition
- Uses common function to read outpc data
- Allow 3-step to be independent.
- Wideband doesn't try to read temperature if no sensor is connected.
- Internal Lambda heater pins now show in usage. (Forced selection.)
- DBW pins now have pin selectors to show in usage. Code uses those for ADCs.
- Custom PWM duty table maxes. Limit max displayed duty. UI tweak.
- Fix a bug where any power off after setting RTC would cause the power hold on to take the full 1.1 seconds.
- Several changes to properly support Axiom 600 hardware around I/O. (toggling pullups, recirc, etc)
- Several changes to make engagement of settings sent from PPC over SPI faster.
- Change USB iManufacturer and iProduct to AxiomEFI
- Change USB product string to be model specific.